Project 07 · Waterproofing
Wet-Area Waterproofing
Bathroom and wet-area waterproofing: bituminous membrane laid and torched on, then flood-tested with standing water to check for leaks. Photographed on site.
- Scope
- Waterproofing
- Photos
- 4, taken on site
- Company
- Free Architecture Fit-out & Interiors, Dubai
- 01
Membrane
1 photo
A bituminous membrane laid across the floor and turned up the walls, sealed around the drain pipe.
- 02
Torch-on
1 photo
Membrane rolls torched on and overlapped strip by strip.
- 03
Flood test
2 photos
The finished membrane flooded with standing water to check for leaks before the floor finishes go on.